11.2.24 SM167 Roller unit Error
This message appears if there is an error at the roller motor (roller prism, type 211). Maybe something
is blocked. After remedying first acknowledge at the roller unit and then at the main unit.
11.2.25 SM168 CAN connection Disconnect!
This message appears if the CAN connection must be interrupted/disconnected (at X18).
11.2.26 SM169 Firmware update required!
This message appears if you have to update the firmware (e.g. via the Config software) because the
firmware of the CAN I/O and the firmware of the drive unit do not match, e.g. because one of the units
was replaced.
11.2.27 SM180 Printer not finished
This message appears if a start signal for web transport was given, the start delay has run off, the
printer, however, is still „busy“ (input X17.5). Check input X17.5 and, as the case may be, the
parameter for the print time (195).
11.2.28 SM181 Chip changed!
This message appears if the chip determining the applicator model was changed or not properly
recognized during operation. Note: When changing the chip all values will be reset to factory /standard
settings. Therefore, if possible, save your settings with the help of the separate configuration program.
11.2.29 SM185 Firmware update Winder required
This message appears if you have to update the firmware in the winder systems in order to fully use
all of their options.
11.2.30 SM186 Label sensor Check signals
This message appears if the label sensor is possibly misadjusted. There is a discrepancy between the
width of the label gap and the label length. As the case may be change from paper to metallized label.
11.2.31 SM187 Quality control Series fault
This message appears if there were too many inadmissable deviations in a row (consecutive error).
Increase the tolerance of deviations. Manually feed labels thereafter. See parameters 186, maybe
944.
11.2.32 SM188 Quality control Stop delay change
This message appears if the overfeed distance (stop delay) was changed inadmissibly. Measure the
label anew by feeding manually.
11.2.33 SM189 Quality control label length wrong
This message appears if the overfeed distance (stop delay) of the label is too long. Measure the label
anew by feeding manually. As the case may be increase the tolerance. See parameters 186, maybe