Technical Data
Operating voltage: 15 – 30V DC
Rated current consumption:
25mA
Output current: max. 20mA
Output voltage low/high:
2.5V / UB - 3.5V
Temperature (operation/storage): 0 – 50°C / -20 – +80°C
Type of protection: IP20
Protection class: III
Protective circuit: Short-circuit protection, inverse-polarity protection
Label material, minimum requirements
Labeling speed Width of the gap
The gap between the labels must have the following dimensions, depending on the labeling speed:
Declaration of Conformity
HERMA GmbH
Geschäftsbereich Maschinen
D-70791 Filderstadt
Germany
We hereby declare that the label sensor FS03 is developed, designed, and manufactured by us in our
sole responsibility in compliance with the following directives.
EC EMC Directive 2014/30/EU
IEC 60947-5-2:2007 (Low-voltage switchgear and controlgear, Control circuit devices and switching
elements - Proximity switches)
16.01.2019
Managing director
~1.600“/min (40 m/min)
~0.08“ (2 mm)
~1.600“/min, ~4.700“/min
min. ~0.1“ (2,5 mm)
~4.700“/min (120 m/min)
min. ~0.12“ (3,0 mm)