Routing > Tracking > Configuration
Routing
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
355
Buttons
Button Meaning
Reload Updates the fields with the values that are saved in the volatile memory
(
RAM
) of the device.
Set Transfers the changes to the volatile memory (
RAM
) of the device and
applies them to the device. To save the changes in the non-volatile
memory, proceed as follows:
Open the
Basic Settings > Load/Save
dialog.
In the table, highlight the desired configuration profile.
If in the "Selected" column the checkbox is
unmarked
, click the
"Select" button.
Click the "Save" button.
Create Opens the "Create" dialog to add a new entry to the table.
In the "Type" field, you specify the type of the tracking object.
Possible values:
–
interface
The device monitors the link status of its physical ports or of its link
aggregation, LRE or VLAN router interface.
–
ping
The device monitors the route to a remote router or end device by
means of periodic ping requests.
–
logical
The device monitors tracking objects logically linked to each other
and thus allows complex monitoring tasks.
In the "Track ID" field, you specify the identification number of the
tracking object.
Possible values:
–
1..2147483647
Remove Removes the highlighted table entry.
Help Opens the online help.