Diagnostics > Status Configuration > Signal Contact > Signal Contact 1
Diagnostics
436
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
9.5.1 Global
Configuration
With the
Manual Setting
mode, you control the signal contact remotely.
This is useful in the following situations, for example:
Simulating an error during SPS error monitoring.
Remote control of a device via SNMP, such as switching on a camera.
Parameters Meaning
Mode Specifies which events the device monitors via the signal contact.
Possible values:
"Manual Setting"
With this mode, you control the signal contact remotely. Closing or
opening the contact turns on or off remote devices, e.g. a remote
camera.
"Monitoring Correct Operation" (default setting)
In this mode, you specify the individual device functions to monitor via
the signal contact. The signal contact thus makes remote diagnosis
possible.
"Device Status"
In this mode, the "Signal Contact Status" frame displays the overall
status of the functions monitored in the
Diagnostics > Status
Configuration > Device Status
dialog.
"Security Status"
In this mode, the "Signal Contact Status" frame displays the overall
status of the functions monitored in the
Diagnostics > Status
Configuration > Security Status
dialog.
"Device Status"/"Security Status"
In this mode, the "Signal Contact Status" frame displays the overall
status of the functions monitored in the
Diagnostics > Status
Configuration > Device Status
dialog and in the
Diagnostics >
Status Configuration
> Security Status
dialog.
Note: To display the current operating status of the signal contact after
changing the configuration mode, first click "Set" then "Reload".
Contact Displays the status of the signal contact.
Possible values:
"Opened"
An event has occurred that triggers the signal contact. The signal
contact is opened.
"Closed"
Normal status. The signal contact is closed.