Diagnostics > Status Configuration > Device Status
Diagnostics
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
423
9.2.2 Port
Table
Buttons
Parameters Meaning
Propagate
Connection Error
Activates/deactivates the monitoring of the link on the port/interface.
Possible values:
marked
Monitoring is active.
The "Device status" changes to "Error" if the link on the selected
port/interface is interrupted.
unmarked
(default setting)
Monitoring is inactive.
This setting takes effect when you mark the "Connection error" checkbox
in the "Global" tab.
Button Meaning
Set Transfers the changes to the volatile memory (
RAM
) of the device and
applies them to the device. To save the changes in the non-volatile
memory, proceed as follows:
Open the
Basic Settings > Load/Save
dialog.
In the table, highlight the desired configuration profile.
If in the "Selected" column the checkbox is
unmarked
, click the
"Select" button.
Click the "Save" button.
Reload Updates the fields with the values that are saved in the volatile memory
(
RAM
) of the device.
Help Opens the online help.