Diagnostics > Status Configuration > Device Status
Diagnostics
422
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
Buttons
External memory
not in sync
Activates/deactivates the monitoring of the configuration profile in the
device and in the external memory.
Possible values:
marked
Monitoring is active.
The "Device status" changes to "Error" in the following situations:
– The configuration profile solely exists in the device.
– The configuration profile in the device differs from the
configuration profile in the external memory.
unmarked
(default setting)
Monitoring is inactive.
Power Supply Activates/deactivates the monitoring of the power supply unit.
Possible values:
marked
(default setting)
Monitoring is active.
The "Device status" changes to "Error" if the device has a detected
power supply fault.
unmarked
Monitoring is inactive.
Button Meaning
Set Transfers the changes to the volatile memory (
RAM
) of the device and
applies them to the device. To save the changes in the non-volatile
memory, proceed as follows:
Open the
Basic Settings > Load/Save
dialog.
In the table, highlight the desired configuration profile.
If in the "Selected" column the checkbox is
unmarked
, click the
"Select" button.
Click the "Save" button.
Reload Updates the fields with the values that are saved in the volatile memory
(
RAM
) of the device.
Help Opens the online help.
Parameters Meaning