EasyManua.ls Logo

Hirschmann HiSecOS EAGLE30 - Syslog

Hirschmann HiSecOS EAGLE30
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics > Syslog
Diagnostics
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
451
Diagnostics > Syslog
9.12 Syslog
The device allows you to report selected events, independent of the severity
of the event, to different syslog servers. In this dialog, you specify the settings
for this function and manage up to 8 syslog servers.
Operation
Table
Parameters Meaning
Operation When the function is switched on, the device sends the events specified
in the table to the specified syslog servers.
Possible values:
"On"
"Off" (default setting)
Parameters Meaning
Index Displays a sequential number to which the table entry relates.
The device automatically assigns this number.
When you delete a table entry, this leaves a gap in the numbering. When
you create a new table entry, the device fills the first gap.
Possible values:
1..8
IP-Address Specifies the IP address of the syslog server.
Possible values:
Valid IPv4 address (default setting:
0.0.0.0
)
Destination UDP
Port
Specifies the UDP Port on which the syslog server expects the log entries.
Possible values:
1..65535
(default setting:
514
)

Table of Contents