Diagnostics > Syslog
Diagnostics
452
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
Buttons
Minimum Severity Specifies the minimum severity of the events. The device sends a log
entry for events with this severity and with more urgent severities to the
syslog server.
Possible values:
emergency
alert
critical
error
warning
(default setting)
notice
informational
debug
Type Specifies the type of the log entry transmitted by the device.
Possible values:
systemlog
(default setting)
audittrail
Active Activates/deactivates the transmission of events to the syslog server:
marked
The device sends events to the syslog server.
unmarked
(default setting)
The transmission of events to the syslog server is deactivated.
Button Meaning
Set Transfers the changes to the volatile memory (
RAM
) of the device and
applies them to the device. To save the changes in the non-volatile
memory, proceed as follows:
Open the
Basic Settings > Load/Save
dialog.
In the table, highlight the desired configuration profile.
If in the "Selected" column the checkbox is
unmarked
, click the
"Select" button.
Click the "Save" button.
Reload Updates the fields with the values that are saved in the volatile memory
(
RAM
) of the device.
Create Adds a new table entry.
Remove Removes the highlighted table entry.
Help Opens the online help.
Parameters Meaning