9.11 Selftest
This dialog allows you to do the following:
Enable/disable the option of entering the system monitor upon the system
start.
Specifies how the device behaves in the case of an error.
Configuration
Note: The following settings block your access to the device permanently
if the device does not detect any readable configuration profile when it is
restarting. This is the case, for example, if the password of the
configuration profile that you are loading differs from the password set in
the device.
"Activate SysMon1" checkbox is
unmarked
.
"Load default config on error" checkbox is
unmarked
.
To have the device unlocked again, contact your sales partner.
Parameters Meaning
Activate SysMon1 Activates/deactivates the access to the system monitor during the restart.
Possible values:
marked
(default setting)
The device allows you to open the system monitor during the restart.
unmarked
The device starts without the option of opening to the system monitor.
Among other things, the system monitor allows you to update the device
software and to delete saved configuration profiles.
Load default config
on error
Activates/deactivates the loading of the delivery settings if the device does
not detect any readable configuration profile when it is restarting.
Possible values:
marked
(default setting)
The device loads the delivery settings (default configuration).
unmarked
The device interrupts the restart and stops. To access the
management functions is possible solely using the CLI through the
V.24 interface of the device.
To regain the access to the device through the network, open the
system monitor and reset the settings. Upon restart, the device loads
the delivery settings (default configuration).