Diagnostics > Report > Persistent Logging
Diagnostics
468
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
Configuration
Parameters Meaning
Max File Size Specifies the maximum size of the log file in KBytes. If the log file attains
the specified size, the device archives this file and saves the following log
entries in a newly created file.
Possible values:
0..4096
(default setting:
1024
)
The value
0
deactivates saving of log entries in the log file.
Maximum Files Specifies the number of log files that the device keeps on the external
memory.
As soon as the specified maximum number of files has been attained, the
device deletes the oldest file and renames the remaining files.
Possible values:
0..25
(default setting:
4
)
The value
0
deactivates saving of log entries in the log file.
Severity Specifies the minimum severity of the events. The device saves the log
entry for events with this severity and with more urgent severities in the log
file on the external memory.
Possible values:
emergency
alert
critical
error
warning
(default setting)
notice
informational
debug
Target Specifies the external memory device for logging.
Possible values:
sd
External SD memory (ACA31)
usb
External USB memory (ACA22)