11. The following message is displayed.
Note: The data transfer will be successful even if the Error. EPSV not
implemented message was indicated during the data transfer.
To restore the configuration data
1. Start the terminal software and connect the target switch module.
2. Enter operator as login name, and then press Enter key.
3. Confirm that the command prompt is indicated.
4. Enter enable, and then press Enter key.
5. Enter restore ftp < IP Address > < backup file name.dat> no-
software, and then press Enter key.
6. Enter upload, and then press Enter key.
7. Enter password, and then press Enter key.
8. The following message is displayed.