Removing a LOM pass through connector.
1. Put on an anti-static wrist strap.
2. Little by little and in sequence, loosen the four screws that hold the LOM
pass through connector. (Sequence 1 -> 2 -> 3 -> 4 -> 1, and so on)
3. Pull out the LOM pass through connector straight upward, and then
remove it.
Figure 5-69 Removing the LOM pass through connector
Installing a LOM pass through connector.
1. Put on an anti-static wrist strap.
2. Reverse the removal procedure.
Replacing a LOM pass through connector in full-wide server
blade
This procedure describes how to remove a LOM pass through connector from
the server blade.
Do not remove screws except for that hold the LOM pass
through connectors.
Do not remove screws except for that hold the LOM pass through
connectors. Work performed by unqualified persons can lead to an electric
shock, fire, or burns. Especially it is hazardous if you touch areas inside
the high-voltage power module.
Note: Use the Phillips screwdriver satisfying the following conditions.
Screw size : 2M
Shaft diameter : 4Φ
Notice:
5-54
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual