Figure 5-65 Restriction for installing to the server blade with LOM
Replacing a mezzanine card in full-wide server blade
This procedure describes how to remove a mezzanine card from the server
blade.
Removing a mezzanine card
1. Put on an anti-static wrist strap.
2. Record the parameters in the case of replacing Emulex HBA card.
See Configuration procedure for Emulex HBA card on page 7-2 section.
3. Remove the target server blade.
See
Removing a full-wide server blade on page 5-6 section.
4. Open the top cover of the server blade. See Opening a top cover, Server
blade on page 5-38 section.
5. Open the lock tabs, as shown below.
6. Grab the mezzanine card shown as arrows A and B, then lift up the
mezzanine card and remove it from the server blade assembly.
Replacing parts
5-51
Hitachi Compute Blade 500 Series System Service Manual