See Maintenance mode on/off procedure on page 4-10 section.
5. Remove a cable from the failed FC port.
6. While holding the pull tab of the optical module, pull out the module
straight forward.
Figure 5-145 Removing an SFP+ module in 16Gb FC switch
Installing an SFP+ module
SFP+ module for LAN switch/8Gb FC switch/DCB switch/LAN pass trough
1. Put on an anti-static wrist strap.
2. If the dust cap is put in the spare SFP+ module as shown in the following
figure, remove it first.
Figure 5-146 Removing the dust cap
3. Close the lever, and then push in the SFP+ module.
Figure 5-147 Installing an SFP+ module
4
. Verify that the replaced SFP is running normally.
Replacing parts
5-115
Hitachi Compute Blade 500 Series System Service Manual