Figure 5-137 Confirming internal LAN
9. Shutdown the failed management module.
See
Management module on page 4-61 section.
10. Remove all cables for the failed management module.
11. Release the blue lock tab and pull the lever, as shown below.
12. Holding the management module, carefully slide out the management
module from the chassis and place it on an anti-static mat.
Figure 5-138 Removing a management module
Installing a management module
1. Put on an anti-static wrist strap.
2. Reverse the removal procedure to install the management module.
3. Connect web console. See
Web console login procedure on page 4-3
section.
4. Turn on the maintenance mode from web console.
Replacing parts