Hitachi CB 520H B3 - Replacing a LOM Pass through Connector in Half-Wide Server Blade

Hitachi CB 520H B3
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 5-68 Installing the mezzanine card
Notice:
You can install the mezzanine card at the slot number 1 or 3 on CB 540A
B1 after removing LOM pass through connector and updating the FRU.
See "Chapter 10, Change LOM configuration".
Replacing a LOM pass through connector in half-wide server
blade
This procedure describes how to remove a LOM pass through connector from
the server blade.
Do not remove screws except for that hold the LOM pass
through connectors.
Do not remove screws except for that hold the LOM pass through
connectors. Work performed by unqualified persons can lead to an electric
shock, fire, or burns. Especially it is hazardous if you touch areas inside
the high-voltage power module.
Note: Use the Phillips screwdriver satisfying the following conditions.
Screw size : 2M
Shaft diameter : 4Φ
Replacing parts
5-53
Hitachi Compute Blade 500 Series System Service Manual