• The TOD clock in switch module is always synchronized with one in
management module according to the user configuration.
This procedure describes how to set up and identify TOD clock of both the
CB500 management module and the BMC in a server blade.
Management Module
To identify TOD;
1. Select Administration tab on the web console and select Date and
Time.
2. Select Local Time tab, Time Zone tab, and NTP tab.
3. Check and record the information for maintenance.
Figure 4-38 Identifying TOD clock information in management
module
To edit Local Time;
1. Select Administration tab on the web console and select Date and
Time.
2. Select Local Time tab and then click Edit.
3. The dialog box for edit appears. Input local time in your environment.
4. Click Submit.
Common process for replacement
4-45
Hitachi Compute Blade 500 Series System Service Manual