To restore the configuration data;
1. Start the terminal software and connect the target switch module.
2. Enter admin as login name, and then press Enter key.
3. Enter password as password, and then press Enter key.
4. Confirm that the command prompt is indicated.
5. Enter copy ftp://upload:password@< IP Address for console PC >/
<download data file name > startup-config, and then press Enter
key.
6. Enter y, and then press Enter key.
7. Enter reload, and then press Enter key.
8. Enter y, and then press Enter key.
9. The following message is displayed.
10. Enter show license, and press Enter to confirm VCS/FCoE licenses.
Confirm whether the indicated licenses include the authorized licenses
which confirmed in the procedure of Confirming NOS version and
VCS/FCoE license of 10Gb DCB switch module before the
replacement.
Common process for replacement
4-43
Hitachi Compute Blade 500 Series System Service Manual