7. Controller Configuration window is displayed. Set up the configuration
of MultiChannel Support and Personality for the replaced card
corresponding with ones of the failed card that you recorded in the
previous procedures.
8. Select Save, and then press Enter.
Note: The Controller number of the replaced CNA or LAN card varies
depending on the server model and the mezzanine card slot#.
Identify the Controller number according to the criteria in the following
table.
Two Controller number are assigned to a CNA or LAN card.
One Controller number is assigned to an onboard LOM.
No. Server model
# of CNA 
1
# of CTRL 
2
Controller #
1 GGAGC0An-
or GGAGB0An-
without LOM
1 2 #0, #1 for the
mezzanine
2 2 3 #0, #1 for Mezz#1
#2, #3 for Mezz#2
3 GGAGC0Bn-
with LOM
0 1
#0 for LOM 
3
1 3
#0 for LOM 
3
#1, #2 for the
mezzanine
4 GGAGD0An-
without LOM
1 2 #0, #1 for the
mezzanine
5 2 4 #0, #1 for first
mezzanine #
#2, #3 for second
mezzanine #
6 3 6 #0, #1 for first
mezzanine #
#2, #3 for second
mezzanine #
#4, #5 for third
mezzanine #
7 4 8 #0, #1 for Mezz #1
#2, #3 for Mezz #2
#4, #5 for Mezz #3
#6, #7 for Mezz #4
8 GGAGD0Bn-
with LOM
0 2
#0, #1 for LOMs 
4
1 4
#0, #1 for LOMs 
4
#2, #3 for the
mezzanine
Configuring Emulex mezzanine card
7-83
Hitachi Compute Blade 500 Series System Service Manual