4 Individual remote controls
PC-ART
TCGB0106 rev.0 - 12/2014
140
E6 Indoor Fan Operation Time After Cooling Operation Stoppage
This function is used to prevent dew condensation “SLOW” indoor fan operation (for 60 minutes or 120 minutes depending
on the setting) while cooling operation is stopped. Additionally, it is effective to prevent fangs or abnormal odor.
E7 Not Prepared
E8 Fan Operation Control at Heating Thermo-OFF
This function is used to prevent the perception of cold draft by reducing indoor fan speed at heating thermo-OFF.
Setting Condition Fan Operation at Thermo-OFF
00 LOW
01 SLOW
E9 Not Prepared
EA Not Prepared
Eb Fan Operation Control at Cooling Thermo-OFF
This function is used to control odor diffusion and humidity level indoor fan speed at cooling thermo-OFF.
Setting Condition Fan Operation at Thermo-OFF
00 Operation at Setting Fan Speed
01 LOW
02 SLOW
EC Forced Thermo-ON Stoppage at Cooling
This function is used to stop operation by forced thermo-ON when cooling operation is stopped. It is effective to prevent
abnormal odor because the heat exchanger is kept in the clean condition such as the heat exchanger is rinsed with drain
water.
Ed Not Prepared
EE Automatic Fan Speed Control
This function is used to economize the operation. The fan speed is automatically controlled when the room temperature is
near the setting temperature.
F1 Automatic OFF Timer Setting
This function is used to set the OFF timer function automatically when the unit is started by the remote control switch.
During operation with the automatic OFF timer setting function, the cancellation of the OFF timer and the changing of the
setting period for OFF timer can not be performed.
However, the OFF timer function is canceled when the unit is stopped. When the unit is operated again after stoppage, the
setting period for OFF timer is set by the optional setting.
The setting condition and the setting period for OFF timer are as shown below.
Setting Condition Setting Period for OFF Timer
00 Function Invalid
01 1 hour
02 2 hours
03 3 hours
Omitted 04 to 21 ...
22 22 hours
23 23 hours
24 24 hours
0A 0.5 hour
0B 1.5 hours
NOTE
This function is not available when controlled by the remote control connecting with CS-NET or 7-day Timer.

Table of Contents

Other manuals for Hitachi PSC-A1T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi PSC-A1T and is the answer not in the manual?

Hitachi PSC-A1T Specifications

General IconGeneral
BrandHitachi
ModelPSC-A1T
CategoryController
LanguageEnglish

Related product manuals