Setting Temperature
1 Select the target group at screen of “Monitor 1 (All Groups)” or “Monitor 2 (Block)” to change the setting temperature.
The pop-up of “Setting” for the selected group is displayed on the touchscreen.
Monitor 1 (All Groups) Monitor 2 (Block)
Monitor 1 (All Groups)
F-Level
1-B
F-Level
1-A
F-Level
2
Annex
25/01/2010 (Mon) 10:20
Group1A-01
Group1A-03
Group1A-05
Group1A-07
Group1A-09
Group1A-11
Group1A-13
Group1A-15
Group1A-02
Group1A-04
Group1A-06
Group1A-08
Group1A-10
Group1A-12
Group1A-14
Buffet 1
North Area
Buffet 1
South Area
Buffet 1
East Area
Buffet 1
West Area
Buffet 2
North Area
Buffet 2
South Area
Buffet 2
East Area
Buffet 2
West Area
Meeting
Room A
Meeting
Room B
Meeting
Room C
Meeting
Room E
Meeting
Room D
Kiosk
Group1A-16
Group1B-03
Group1B-05
Group1B-07
Group1B-09
Group1B-11
Group1B-13
Group1B-02Group1B-01
Group1B-04
Group1B-06
Group1B-08
Group1B-10
Group1B-12
Group2-01
Group2-03
Group2-05
Group2-07
Group2-09
Group2-11
Group2-02
Group2-04
Group2-06
Group2-08
Group2-10
Menu
All Groups
Setting
All Groups
Run
All Groups
Stop
(1)
Menu
25/01/2010 (Mon) 10:20
Monitor 2 (Block)
Setting by
Block
Run by
Block
Stop by
Block
26
DRY LOW
Group1A-01
All Groups Annex
F-Level
1-A
F-Level
1-B
F-Level
2
24
DRY LOW
Group1A-05
20
DRY LOW
Group1A-09
22
DRY LOW
Group1A-13
26
DRY LOW
Group1A-02
24
DRY
LOW
Group1A-06
20
DRY LOW
Group1A-10
20
DRY LOW
Group1A-14
20
DRY LOW
Group1A-03
26
DRY
LOW
Group1A-07
26
DRY LOW
Group1A-11
19
DRY LOW
Group1A-15
25
DRY LOW
Group1A-04
26
DRY
LOW
Group1A-08
23
DRY LOW
Group1A-12
22
DRY LOW
Group1A-16
AUTO
AUTO
AUTO
AUTO
(1)
2 By tapping “ ”, the temperature is increased by 1 ºC. (Max. 30 ºC). By tapping “ ”, the temperature is decreased by
1 ºC.
At Cooling, Dry and Fan operation: Min. 19 ºC
At Heating operation: Min. 17 ºC
3 Tap “Close” to return to the screen of “Monitor 1 (All Groups)” or “Monitor 2 (Block)”.
Close
26
DRY LOW
RUN
STOP
F-Level 1-A
Group1A-02
AUTO
Setting
Operation
Setting
RCS Operation
Prohibited
RUN/STOP OPE. MODE
FAN SPEED
LOUVER SET TEMP.
(3)
(2)
NOTE
In the case of “Run/Stop Only” mode, setting change is available by only “All Groups Setting” or “Setting by Block” button. (Setting
change for each group is NOT available).
The gure above shows an example of the setting temperature for the standard unit. The temperature setting range may be different
depending on the connected indoor units.