193
Use the undo opaque-capability command to restore the default.
By default, the opaque LSA capability of OSPF is disabled.
Syntax
opaque-capability enable
undo opaque-capability
View
OSPF view
Default level
2: System level
Parameters
enable: Enables the opaque LSA capability.
Examples
# Enable the opaque LSA capability of OSPF.
<Sysname> system-view
[Sysname] ospf 100
[Sysname-ospf-100] opaque-capability enable
ping lsp te
Description
Use the ping lsp te command to check the validity and reachability of the MPLS TE tunnels on a tunnel
interface.
Syntax
ping lsp [ -a source-ip | -c count | -exp exp-value | -h ttl-value | -m wait-time | -r reply-mode | -s packet-
size | -t time-out | -v ] * te interface-type interface-number
View
Any view
Default level
0: Visit level
Parameters
-a source-ip: Specifies the source IP address of the Echo Request messages to be sent.
-c count: Specifies the number of Echo Request messages to be sent. The count parameter ranges from 1
to 4,294,967,295 and defaults to 5.
-exp exp-value: Specifies the EXP value for the Echo Request messages. The exp-value parameter ranges
from 0 to 7 and defaults to 0.
-h ttl-value: Specifies the TTL value for the Echo Request messages. The ttl-value parameter ranges from 1
to 255 and defaults to 255.
-m wait-time: Specifies the interval for sending Echo Request messages. The wait-time parameter ranges
from 1 to 10,000 and defaults to 200, in milliseconds.

Table of Contents

Other manuals for HP 5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5800 Series and is the answer not in the manual?

HP 5800 Series Specifications

General IconGeneral
MAC Address Table Size32, 000 entries
Uplink Ports2 or 4 SFP+ 10GbE ports
Routing ProtocolBGP, IS-IS
Input Voltage100-240 VAC
Operating Temperature0°C to 45°C
Operating Humidity10% to 95% (noncondensing)
PoEOptional
Power SupplyRedundant power supply (optional)

Related product manuals