Sets and queries the type of preset to execute when the
SYSTem:PRESet[:EXECutel
command is given. Factory preset
defaults all values to factory specified values. User defined preset
defaults all values to a specified state of the swept signal generator
that you have saved with
SYSTem:PRESet : SAVE.
l
SYSTem:SECurity:COUNt
<num>lMINimumlMAXimum
l
SYSTem:SECurity:COUNt?
CMINimumlMAXimum]
Sets and queries the number of times to clear memory when the value
of SYSTem:SECurity[:STATe] changes from ON to OFF.
*RST value is 1.
l
SYSTem:SECurity[:STATel
ONlOFFlllO
l
SYSTem:SECurity[:STATe]?
Controls the security mode of the swept signal generator. When
in secure mode, any display annunciators that have been disabled
cannot be re-enabled without destroying certain stored information.
This value is not affected by *RST. When you change the value
from ON to OFF, everything except calibration data is initialized or
destroyed. In particular, data in instrument state and all save/recall
registers are destroyed.
l
SYSTem:VERSion?
This query returns a formatted numeric value corresponding to the
SCPI version number to which the swept signal generator complies.
The response has the form YYYY.V where the Ys represent the year
version (i.e. 1990) and the V represents an approved revision number
for that year. This is a query only and therefore does not have an
associated *RST state.
l
TRIGger[:IMMediate]
Causes the trigger event to occur regardless of other settings in the
subsystem. This event does not affect any other settings in this
subsystem.
This command has no effect unless the swept signalgeneratorisin
the wait for trig state. If the swept signal generator is in the wait for
trig state, it performs its trigger action. This is an event and has no
*RST condition.
l
TRIGger:ODELay
<num>[time
suffix]
IMAXimumlMINimum
l
TRIGger:ODELay.
7
[MAXimumlMINimum]
Sets and queries the trigger output delay, the time between when
the source is settled, (when Bit 1 of the Standard Operation Status
Register makes a negative transition), and the trigger out signal is
sent.
S-54 Operating and Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8360 B Series and is the answer not in the manual?

HP 8360 B Series Specifications

General IconGeneral
BrandHP
Model8360 B Series
CategoryPortable Generator
LanguageEnglish

Related product manuals