3. Verify that the DC SAN Director is functioning correctly by typing switchShow or switchStatusShow.
This switchShow command displays DC SAN Director and port status information.
rsl8-st03-dcx-1:admin> switchshow
switchName: rsl8-st03-dcx-1
switchType: 62.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 11
switchId: fffc0b
switchWwn: 10:00:00:05:1e:39:59:67
zoning: OFF
switchBeacon: OFF
blade3 Beacon: OFF
blade5 Beacon: OFF
blade8 Beacon: OFF
blade10Beacon: OFF
Index Slot PortAddressMediaSpeedStateProto
===========================================================
32 3 00b2000idN4OnlineL-Port 5 public
33 3 10b2100__N8No_Module
34 3 20b2200__N8No_Module
35 3 30b2300__N8No_Module
36 3 40b2400idN4OnlineF-Port
10:00:00:00:c9:51:00:2d
37 3 50b2500__N8No_Module
rsl8-st03-dcx-1:admin>
4. Verify that all the IP address information is correct by typing ipAddrShow and checking the results
against the IP information recorded in the config-miscinfo.txt file.
rsl8-st03-dcx-1:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>