CA sets the parameters for the local and the remote serial console. Input and output data rates
are the same. The value returned by the stty command on HP-UX is the local serial port console
speed.
Set up the local serial port parameters as follows:
BAUD RATES Input and output data rates are the same. Possible values are as follows:
4800, 9600, 19200, 38400, 115200 bit/sec.
FLOW
CONTROL
Hardware uses RTS/CTS; software uses Xon/Xoff.
For HP Integrity server blades, the CA command also provides an option to change between the
Integrity iLO mode or the dedicated AUX UART mode. Switching to AUX UART mode when
MP remote access is disabled or LAN parameters are not configured requires a push button reset
to change back to iLO MP mode.
NOTE: Inconsistent bit rate settings can result in improper MP UI while switching between
these modes.
The operation mode settings are saved on the MP NVRAM and are permanent for reset and
firmware upgrade of iLO 2, but the settings are not permanent for power cycles or blade ejection.
For power cycle to the blade, the console serial port is set back to the iLO mode.
If you cannot access iLO 2 through Telnet and the port mode of operation is AUX UART, you
must change the port operation mode to Integrity iLO mode to access the MP through the serial
port. To change the port operation mode to iLO, perform a hard reset to the MP by pushing the
recessed push button through a hole in the front panel. The hard reset resets the MP hardware
and sets the MP to the default settings. The hard reset returns the port default connection to MP.
NOTE: Both short and long reset button presses return the port default connection to the MP.
The iLO 2 mirrors the system console to the iLO 2 MP local and LAN ports. One console output
stream is reflected to all connected console users. If several different terminal types are used
simultaneously, some users can see unexpected results.
Command line usage and scripting:
CA [ -local ] [ -bit <n> ] [ -flow >software|hardware> ] ] [ -nc ]
-?
Server blade usage
CA [ -local ] [ -bit <n> ] [ -flow >software|hardware> ]
[ -mode ,aux|ilo> ] ] [ -nc ]
-?
See also: SA
DATE: Display date
Command access level: Login access
DATE displays the date, as best known to iLO 2. The iLO 2 clock is updated from the BMC/SFW
and cannot be modified. The realtime clock is used only when iLO 2 is first powered on or
rebooted, until it can obtain the correct date from the BMC.
Command line usage and scripting:
DATE [ -nc ]
-?
DC (Default Configuration): Reset all parameters to default configurations
Command access level: MP configuration access
Text User Interface 95

Table of Contents

Other manuals for HP Integrity BL870c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL870c and is the answer not in the manual?

HP Integrity BL870c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL870c
CategoryServer
LanguageEnglish

Related product manuals