EDGE Pro Ti CNC Instruction Manual 807660 109
Maintenance and Diagnostics
Diagnostic tests
To test I/O contacts:
1. On the Machine Interface screen, choose the I/O port you want to test.
2. Follow the instructions on the screen to connect the test plug into the I/O port you selected on the back of the CNC.
3. Press Test. A message informs you if the test is successful.
4. If the first test fails, follow the instructions on the screen to conduct the second test and isolate the I/O points that
are causing the problem.
5. If the second test fails, the screen reports the number of the failed input or output. Contact your table manufacturer to
replace the I/O board (141278).