110 EDGE Pro Ti CNC Instruction Manual 807660
Maintenance and Diagnostics
Diagnostic tests
Plasma and lifter tests
The plasma and lifter tests use the same tester. Conduct this test to verify that the plasma and lifter interfaces are
performing as expected.
Figure 61 Plasma and lifter interface tester
To test the plasma or lifter interface:
1. On the Machine Interface screen, choose the plasma or lifter interface on the back of the CNC.
2. Follow the instructions on the screen to install the tester on the back of the CNC.
3. Press Test. A message informs you if the test is successful.
4. If the test fails, replace the I/O relay board (141278) or the utility and serial isolation board (141307).