80 EDGE Pro Ti CNC Instruction Manual 807660
Installation
Plasma connection
Plasma connection for generic plasma systems
To connect the plasma interface on the EDGE Pro Ti CNC to any plasma system that does not have a compatible voltage
divider, install the generic plasma interface cable between the plasma interface on the EDGE Pro Ti and the 15-pin
D-sub connector (P1) on the plasma interface assembly (228256) in the plasma system. Refer to Plasma interface
assembly (228256) on page 82 for information about the plasma interface assembly and how to install and wire it.
Figure 41 Generic plasma interface cable to the plasma interface assembly (228256)
Figure 42 Generic plasma interface cable
Plasma interface
cable
Plasma interface assembly
(228256)
Diameter = 7.213 mm (0.284 in.)
Bend radius = 150 mm (6 in.)
1
15