90 EDGE Pro Ti CNC Instruction Manual 807660
Installation
Lifter interface
Table 21 Pinouts for lifter interface cable
Use the following information to order the lifter interface cable.
Pin
number
Signal Wire color Dry contact circuit
1 +12 VDC Black
2 Upper Limit switch (shared with input 11) White Normally
open
3 Field Common Red
6 Lower Limit switch (shared with input 12) Blue
3 Field Common Red
7 Breakaway switch Orange
3 Field Common Red
8 Field Common Yellow
4 Nozzle contact -12 V Green
9 Nozzle contact sense Violet
5 Nozzle contact common Brown
Part Number Length
223343 3.05 m (10 ft)
223344 6.08 m (20 ft)
223345 7.62 m (25 ft)
223346 10.66 m (35 ft)
123968 10.97 m (36 ft)
123897 15.25 m (50 ft)