98 EDGE Pro Ti CNC Instruction Manual 807660
Operation
Updating Phoenix software
To back up modified cut charts:
1. At the CNC, plug a memory stick into a USB port.
2. On the Main screen, choose one of the cut chart soft keys, such as Plasma 1 Cut Chart.
3. Choose the Save Cut Charts soft key. Phoenix copies all the cut charts associated with the Plasma 1 Torch Type
onto the memory stick.
To update the cut charts:
1. At the CNC, plug the memory stick that contains the file CutChart.exe into a USB port.
Note: Verify that CutChart.exe resides in the root folder of the memory stick.
2. On the Main screen, choose Process, and choose one of the cut chart soft keys such as Plasma 1 Cut Chart.
3. Choose the Load Cut Charts soft key, then choose Yes when prompted to load cut charts from the memory stick.
Phoenix extracts the cut charts and copies them to the hard drive.
4. If you have modified cut charts to copy back onto the hard drive, you will need to exit Phoenix and use Windows®
Explorer to copy your .usr files back onto the hard drive. The cut chart folder is c:\Phoenix\CutCharts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm EDGE Pro Ti and is the answer not in the manual?

Hypertherm EDGE Pro Ti Specifications

General IconGeneral
BrandHypertherm
ModelEDGE Pro Ti
CategoryControl Systems
LanguageEnglish

Related product manuals