Chapter 8. Storage pools 319
򐂰 The internal drives in IBM Flex System V7000 Storage Node can be assigned to several
usage roles, which either can be unused, candidate, spare, or failed:
Unused: The drive is not member of an MDisk (array).
Candidate: The drive is available for use in an array.
Spare: The drive can be used as a hot spare if required.
Failed: The drive was either intentionally taken offline or failed due to an error.
Click Mark as... in the Actions drop-down menu, and select the role you want the drive to
be assigned to (Figure 8-7).
Figure 8-7 Change a drives usage
򐂰 Use the Identify action (in Figure 8-7) to turn on the LED light so you can physically
identify a drive that needs to be replaced, or that you want to troubleshoot.
Internal drives: Choosing the option to take internal drives offline could lead to
potential data loss.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities