3 Analog I/O Modules
30-26 WindO/I-NV4 User’s Manual
● Analog Output Module
Allocation of device address for the analog output module is shown below.
For details about the parameter setting values, refer to “ Analog Output Parameter Setting Values” on page 30-26.
Analog Output Parameter Setting Values
The parameter setting values are as follows.
■ Signal type
If the setting value is outside the range, a parameter setting error will occur.
■ Data type
If the setting value is 2 to 65,535, a parameter setting error will occur.
■ Minimum and maximum values
The minimum and maximum values can be set only when the data type is set to optional range. Set the minimum and
maximum values between -32,768 and 32,767.
Channel
Parameter R/W
FC6A-K2A1 FC6A-K4A1
No. Address Number Address Number
CH0
Analog output data R +0 +0
Analog output status R +1 +1
CH1
Analog output data R +2 +2
Analog output status R +3 +3
CH2
Analog output data R ― +4
Analog output status R ― +5
CH3
Analog output data R ― +6
Analog output status R ― +7
Setting Value Signal Type
0 Unused
1 0 to 10 V
2 -10 to +10 V
3 0 to 20 mA
4 4 to 20 mA
Setting Value Data type
0 Binary data
1Optional range