EasyManua.ls Logo

IDTECK iTDC - Page 75

IDTECK iTDC
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
p.68
BASIC SETTING
iTDC
CODE_
CODE is to enter ID type. Each ID is divided into 4 types: (0) for normal user, (1) for
Group #1 of 2 men operation mode, (2) for Group #2 for 2 men operation mode, (3)
for special ID which can be used to set ARM/DISARM or control double door time.
1. [TWO MEN MODE]: “NOTUSE” / [ARM/DISARM CODE]: “00”
The group #1 ID (1) and group #2 ID (2) perform same operation with general user
(0).
The special ID (3) occurs settings of [READER DEFINE] / 17.R1 SPECIAL ID ~ 20. R4
SPECIAL ID in [SETUP MODE F2].
2. [TWO MEN MODE]: “NOTUSE” / [ARM/DISARM CODE]: Any 2digit no. (except “00”)
The group #1 ID (1) and group #2 ID (2) perform same operation with general user.
The special ID (3) is used to set “ARM/DISARM ”. But the special ID (3) is used as
general user (0) if the special ID (3) is authorized to the iTDC /iTDC-SR with not
entering “ARM/DISARM CODE”.
3. [TWO MEN MODE]: “USE” / [ARM/DISARM CODE]: “00”
Make sure that make the group #1 ID (1) and the group #2 (2) present. If you so, the
iTDC/iTDC-SR permits to access of two group IDs. The special ID (3) occurs settings of
[READER DEFINE] / 17.R1 SPECIAL ID ~ 20. R4 SPECIAL ID in [SETUP MODE F2].
4. [TWO MEN MODE]: “USE” / [ARM/DISARM CODE]: Any 2digit no. (except “00”)
Make sure that make the group #1 ID (1) and the group #2 (2) present. If you so, the
iTDC/iTDC-SR permits to access of two group IDs. The special ID (3) is used to set
“ARM/DISARM ”. But the special ID (3) is used as general user (0) if the special ID (3) is
authorized to the iTDC / iTDC-SR with not entering “ARM/DISARM CODE”. To use
general access control system, input “0” for all users.
Please refer to more information of initialization setting value in 11. APPENDIX .
TA__TB__TC__TD__
TA, TB, TC and TD are Time Schedule code (00-15) for the Readers, TA is the Time
Schedule for the Reader #1, TB is for Reader #2, TC is for Reader #3 and TD is for
Reader #4. When you present the card to Reader #1 then the cardholder is only
allowed the access of the door during the Time Schedule code entered to TA__ and
the other Readers are the same manner. To control the accessible Time Schedule for
each cardholder, you must set-up the Time schedules first and enter the Time Schedule
code here.
If you want to access the door anytime for the cardholder then enter default Time