p.68
BASIC SETTING
iTDC
CODE_
CODE is to enter ID type. Each ID is divided into 4 types: (0) for normal user, (1) for
Group #1 of 2 men operation mode, (2) for Group #2 for 2 men operation mode, (3)
for special ID which can be used to set ARM/DISARM or control double door time.
1. [TWO MEN MODE]: “NOTUSE” / [ARM/DISARM CODE]: “00”
The group #1 ID (1) and group #2 ID (2) perform same operation with general user
(0).
The special ID (3) occurs settings of [READER DEFINE] / 17.R1 SPECIAL ID ~ 20. R4
SPECIAL ID in [SETUP MODE F2].
2. [TWO MEN MODE]: “NOTUSE” / [ARM/DISARM CODE]: Any 2digit no. (except “00”)
The group #1 ID (1) and group #2 ID (2) perform same operation with general user.
The special ID (3) is used to set “ARM/DISARM ”. But the special ID (3) is used as
general user (0) if the special ID (3) is authorized to the iTDC /iTDC-SR with not
entering “ARM/DISARM CODE”.
3. [TWO MEN MODE]: “USE” / [ARM/DISARM CODE]: “00”
Make sure that make the group #1 ID (1) and the group #2 (2) present. If you so, the
iTDC/iTDC-SR permits to access of two group IDs. The special ID (3) occurs settings of
[READER DEFINE] / 17.R1 SPECIAL ID ~ 20. R4 SPECIAL ID in [SETUP MODE F2].
4. [TWO MEN MODE]: “USE” / [ARM/DISARM CODE]: Any 2digit no. (except “00”)
Make sure that make the group #1 ID (1) and the group #2 (2) present. If you so, the
iTDC/iTDC-SR permits to access of two group IDs. The special ID (3) is used to set
“ARM/DISARM ”. But the special ID (3) is used as general user (0) if the special ID (3) is
authorized to the iTDC / iTDC-SR with not entering “ARM/DISARM CODE”. To use
general access control system, input “0” for all users.
※ Please refer to more information of initialization setting value in 11. APPENDIX .
TA__TB__TC__TD__
TA, TB, TC and TD are Time Schedule code (00-15) for the Readers, TA is the Time
Schedule for the Reader #1, TB is for Reader #2, TC is for Reader #3 and TD is for
Reader #4. When you present the card to Reader #1 then the cardholder is only
allowed the access of the door during the Time Schedule code entered to TA__ and
the other Readers are the same manner. To control the accessible Time Schedule for
each cardholder, you must set-up the Time schedules first and enter the Time Schedule
code here.
※ If you want to access the door anytime for the cardholder then enter default Time