IS810N-INT Series Servo System User Manual (Brief)Chapter 6 Commissioning Software
- 193 -
Click
Axis 1
in
Axes
, select
Parameter
and set the scaling parameter of the device axis. In
this example, set the required movement unit to 60 mm per revolution of the servo motor, and
the value of
Scaling Factor Numerator
to 60/1048576 (same for the other axis).
Click
Axis 1
in
Axes
, select
Parameter
, and temporarily shield the system deviation (same
for the other axis).