IS810N-INT Series Servo System User Manual (Brief)Appendix 1 List of Object Groups
- 269 -
Parameter group
Name
Option
Description
Setting Range Default Min. Unit Width
Change
method
Effective
Way
Hexadecimal Decimal
Group Index Parameter
2002
10h H02-15
LED warning
display
selection
0: Immediate
output a
warning
message
1: Without
outputting
a warning
message
0 to 1 0 1 16 bits At stop Immediate
11h H02-16
Brake
enabling
switch
0: Off
1: On
0 to 1 0 1 16 bits At stop Immediate
1Fh H02-30
User
Password
- 0 to 65535 0 1 16 bits
During
running
Immediate
20h H02-31
Parameter
initialization
0: No
operation
1: Restore
factory
settings
2: Clear the
fault record
0 to 2 0 1 16 bits At stop Immediate
21h H02-32
H0B group
function code
selection
- 0 to 99 50 1 16 bits
During
running
Immediate
24h H02-35
Panel data
refresh rate
- 0 to 20 0 1 HZ 16 bits
During
running
Immediate
2Ah H02-41
Factory
password
- 0 to 65535 0 1 16 bits
During
running
Immediate
2003h/H03 Terminal input parameters
2003 03h H03-02
DI1 terminal
function
selection
Description:
It consists of
three digits,
the rst one
(from left to
right) indicates
the axis
number, and
the last two
digits indicate
the terminal
function. The
last two digits
are dened as
follows:
0: No
denition
01: S-ON
14: Forward
limit switch
15: Reverse
limit switch
31: Home
switch
38: Probe 1
39: Probe 2
0 to 65535 0 1 16 bits
During
running
Upon stop