IS810N-INT Series Servo System User Manual (Brief)Appendix 1 List of Object Groups
- 269 -
Parameter group
Name
Option
Description
Setting Range Default Min. Unit Width
Change
method
Effective
Way
Hexadecimal Decimal
Group Index Parameter
2002
10h H02-15
LED warning
display
selection
0: Immediate
output a
warning
message
1: Without
outputting
a warning
message
0 to 1 0 1 16 bits At stop Immediate
11h H02-16
Brake
enabling
switch
0: Off
1: On
0 to 1 0 1 16 bits At stop Immediate
1Fh H02-30
User
Password
- 0 to 65535 0 1 16 bits
During
running
Immediate
20h H02-31
Parameter
initialization
0: No
operation
1: Restore
factory
settings
2: Clear the
fault record
0 to 2 0 1 16 bits At stop Immediate
21h H02-32
H0B group
function code
selection
- 0 to 99 50 1 16 bits
During
running
Immediate
24h H02-35
Panel data
refresh rate
- 0 to 20 0 1 HZ 16 bits
During
running
Immediate
2Ah H02-41
Factory
password
- 0 to 65535 0 1 16 bits
During
running
Immediate
2003h/H03 Terminal input parameters
2003 03h H03-02
DI1 terminal
function
selection
Description:
It consists of
three digits,
the rst one
(from left to
right) indicates
the axis
number, and
the last two
digits indicate
the terminal
function. The
last two digits
are dened as
follows:
0: No
denition
01: S-ON
14: Forward
limit switch
15: Reverse
limit switch
31: Home
switch
38: Probe 1
39: Probe 2
0 to 65535 0 1 16 bits
During
running
Upon stop

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS810N-INT Series and is the answer not in the manual?

Inovance IS810N-INT Series Specifications

General IconGeneral
BrandInovance
ModelIS810N-INT Series
CategoryServo Drives
LanguageEnglish

Related product manuals