IS810N-INT Series Servo System User Manual (Brief)Chapter 3 Installation
- 59 -
Figure 3-5 IS810N50M4T****INT (SIZE 3) overall dimensions
Front view
Left view
200
400
305
Top view
200
305
7
4-
384
350
II. Space Requirements
Power supply units are divided into book-type units (100 mm, 200 mm and 300 mm wide)
and vertical units (180 mm wide). The recommended installation methods are single-layer
installation and two-layer installation. The following table shows the minimum clearance
between two layers during two-layer installation. An insulation deector must be installed in
the lower layer.
Table 3-1 Minimum clearance for power supply unit installation
Item
100 mm wide unit 200 mm wide unit 300 mm wide unit 180 mm wide unit
Book-type unit Vertical unit
S1 ≥ 300 mm ≥ 300 mm ≥ 300 mm ≥ 300 mm
S2 ≥ 300 mm ≥ 300 mm ≥ 300 mm ≥ 500 mm
S3 ≥ 300 mm ≥ 300 mm ≥ 300 mm -