Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F9-49 63793
Fault protection action
selection 2
Ones: Communication fault (E16)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Tens: Reserved
5: Disabled
Hundreds: Reserved
0: Coast to stop
Thousands: Motor auto-tuning fault
(E19)
0: Coast to stop
4: Warning
5: Disabled
Ten thousands: Reserved
5: Disabled
50050 -
At stop
F9-49
on page
304
F9-50 63794
Fault protection action
selection 3
Ones: EEPROM read-write fault
(E21)
0: Coast to stop
Tens: Motor auto-tuning result alarm
(E22)
0: Coast to stop
Hundreds: Short circuit to ground
(E23)
0: Coast to stop
5: Disabled
Thousands: Reserved
5: Disabled
Ten thousands: Power supply unit
fault (E25)
2: Special action
5: Disabled
25000 -
At stop
F9-50
on page
305