Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F9-52 63796
Fault protection action
selection 5
Ones: PID feedback loss during
running
(E31)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Tens: Reserved
5: Disabled
Hundreds: Reserved
5: Disabled
Thousands: Excessive speed deviation
(E42)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Ten thousands: Motor overspeed (E43)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
551 -
At stop
“
F9-52
”
on page
307
F9-53 63797
Fault protection action
selection 6
Ones: Motor overtemperature (E45)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Tens: Reserved
5: Disabled
Hundreds: Reserved
5: Disabled
Thousands: Reserved
5: Disabled
Ten thousands: Fan fault (E80)
0: Coast to stop
1: Decelerate to stop
5: Disabled
5500 -
At stop
“
F9-53
”
on page
307
F9-54 63798
Frequency selection for
continuing to run upon
fault
0: Current running frequency
1: Frequency reference
2: Frequency upper limit
3: Frequency lower limit
4: Alternative frequency upon
exception
1 - At once
“
F9-54
”
on page
308
F9-55 63799
Backup frequency
reference
0.0% to 100.0% 100.0 % At once
“
F9-55
”
on page
308
F9-57 63801
Motor overheat
protection threshold 1
0°C to 200°C 110 °C At once
“
F9-57
”
on page
309
List of Drive Unit Parameters
-174-