7 Tools and Setting/Serviceman Menu
7-16
• Timer:
An alarm sounds at the time preset here.
• Vector:
Danger detection vector in minute
The min and NM can be changed when clicking a Vector Length unit button.
Last input value for the unit is displayed when changing a unit.
• Sector:
Sector radius in nm and the angle width in degree (up to 359.9 degrees)
*: For vector and angle width, see 3.27.3 “Danger Detection Vector and Sector”.
The min and NM can be changed when clicking a Sector Radius unit button.
Last input value for the unit is displayed when changing a unit.
• Low Speed Alarm
It is displayed only when setting TCS TOKIMEC category B in Auto Pilot.
When making valid, the alarm occurs when through-the-water speed declines from the set
value.
b) Area (S-57/C-MAP Only)
You can set whether or not to display an alarm on the screen when a symbol on the chart
contacts a danger detection vector by setting each of the items ON and OFF.
Subjects of the items are as follows:
• Traffic separation zone
• Traffic crossing
• Traffic roundabout
• Traffic precautionary
• Two Way traffic
• Deeper water route
• Recommended traffic lane
• Inshore traffic zone
• Fairway
• Restricted area
• Caution area
• Offshore production area
• Military practice area
• Seaplane landing area
• Submarine transit area
• Ice area
• Channel
• Fishing ground
• Fishing prohibited
• Pipeline area
• Cable area
• Anchorage area
• Anchorage prohibited
• Spoil ground
• Dumping ground
• Dredge area
• Cargo transshipment area
• Incineration area
• Specially protected area