Remarks:
*1: Category
*2: Message (detailed description of alarm)
When an alarm occurs, the alarm button blinks in red. At the same time, the detailed description
of the alarm is displayed in the message box at the bottom of the chart display area. When the
Alarm button on the operation panel is pressed to acknowledge the alarm, the blinking alarm
stops and stays lit.
The following table shows the alarm display on the button, in the message box and the “Alarm
List” panel. The “Alarm List” panel opens when the [Alarm List] button is left-clicked.
Alarm button [Alarm List] button
Alarm display
[Alarm buttons on the display panel]
Button/Panel
/Buzzer
Attribution
Alarm button
Alarm
display
Icon on Status
of “Alarm List” panel
Icon on Log
of “Alarm List” Panel
Buzzer
Not acknowledged Red blinking Stay red Red blinking Red blinking Generated
Alarm
Acknowledged Not indicate Stay red Stay red Stay red Silent
Invalid Information Blue blinking Stay blue Stay blue Stay blue Generated
Information with low integrity/ Warning Not indicate Stay yellow Stay yellow Stay yellow Silent
Normal State Stay green Stay green - - Silent
*3: An alarm shown in the “Alarm List” panel.
*4: Audible sound from the dedicated keyboard. The sounding pattern varies with the type of alarm.
Volume of the alarm is changeable every type. ([(7)Main] – [(0)Setting] – [(0) Buzzer Setting])
*5: [A]: Alarm used for TCS only, [V]: Alarm detected by the danger detection vector (vector area),
[S]: Alarm detected by the guard ring (sector area)
*6: Condition to detect an alarm may depend on the hardware to be used.