Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_CONFIG_RECONFIG_ERROR
System Log Message Re-configuration failed, using previous values
Description The alarm process (alarmd) could not parse new configuration and used previous values.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_CONNECTION_FAILURE
System Log Message after count attempts process-name connect returned error: error-message
Description The alarm process (alarmd) was unable to connect to the indicated process
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
ALARMD_DECODE_ALARM_OBJECT_ERROR
System Log Message Cannot decode error test from object alarm-object, reason alarm-reason for if_name
interface-type
Description The alarm process (alarmd) encountered invalide alarm object.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_EXISTS
System Log Message alarmd already running; exiting
Description The alarm process (alarmd) exited because it discovered that another alarmd process
is already running.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
Copyright © 2010, Juniper Networks, Inc.60
Junos 10.3 System Log Messages Reference