ALARMD_EXISTS_TERM_OTHER
System Log Message Killing existing alarmd and exiting
Description The alarm process (alarmd) discovered that another alarmd process is already running.
It terminated the other process and exited.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
ALARMD_IFDALARM_TYPE_ERROR
System Log Message Unknown interface alarm type: alarm-type
Description The alarm process (alarmd) could not recognize an interface type alarm due to it's
unknown alarm type.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_IFDEV_RTSLIB_FAILURE
System Log Message function-name: library-function-name failed on error-message socket (socket-option)
Description The alarm process (alarmd) failed to access an interface device because an error occurred
during the indicated call to the routing socket library.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_IPC_MSG_ERROR
System Log Message function-name: error code error-code, type message-type, subtype message-subtype,
opcode message-opcode
Description The alarm process (alarmd) detected an error in an interprocess communication (IPC)
message with the indicated characteristics.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
61Copyright © 2010, Juniper Networks, Inc.
Chapter 3: ALARMD System Log Messages