Action Verify that the configured continuity-check transmission interval does not differ from the
remote endpoint, and that the configured MEP ID is valid.
CFMD_CCM_DEFECT_MAC_STATUS
System Log Message CFM defect: error-message
Description A connectivity-fault management (CFM) maintenance endpoint (MEP) received a
continuity check message (CCM) that contained a 'Port Status' or 'Interface Status' type,
length, value (TLV), which indicate a failed bridge port or aggregated port.
Type Event: This message reports an event, not an error
Severity error
Facility ANY
CFMD_CCM_DEFECT_NONE
System Log Message CFM defect: error-message
Description No defect was detected.
Type Event: This message reports an event, not an error
Severity error
Facility ANY
CFMD_CCM_DEFECT_RDI
System Log Message CFM defect: error-message
Description A connectivity-fault management (CFM) maintenance endpoint (MEP) received a
continuity check message (CCM) that had the 'Remote Defect Indication' (RDI) bit set,
which indicates that not all configured MEPs are returning CCMs to the transmitting MEP.
Type Event: This message reports an event, not an error
Severity error
Facility ANY
CFMD_CCM_DEFECT_RMEP
System Log Message CFM defect: error-message
Description A connectivity-fault management (CFM) maintenance endpoint (MEP) did not receive
three consecutive continuity check message (CCM)s from one of the other MEPs in its
maintenance association (MA), which indicates a MEP failure or network failure.
Type Event: This message reports an event, not an error
Severity error
Facility ANY