Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_BLOWERS_SPEED
System Log Message Fans and impellers are now running at normal speed
Description The fans (and impellers, if applicable) were running at the normal speed.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_BLOWERS_SPEED_FULL
System Log Message Fans and impellers being set to full speed [reason]
Description For the indicated reason, the chassis process (chassisd) increased the speed of fans
(and impellers, if applicable) to the maximum.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_BLOWERS_SPEED_MEDIUM
System Log Message Fans and impellers being set to intermediate speed
Description The chassis process (chassisd) increased the speed of fans (and impellers, if applicable)
to the intermediate level because of a temperature increase in the chassis.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_BUS_DEVICE_OPEN_FAILURE
System Log Message Unable to open 'bus-type' bus device, error error-message (error-code)
Description The chassis process (chassisd) could not open the indicated bus device for the indicated
reason.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
135Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages