Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_CLOCK_NOTICE
System Log Message fru-name: message
Description The clock-synchronization status of the indicated component (field-replaceable unit or
FRU) changed as indicated.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_CLOCK_RESET_FAIL
System Log Message Zarlink module on Taz Base Board is not coming up after reset
Description The chassis process (chassisd) detected an error in the state of clock module.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_CMB_READBACK_ERROR
System Log Message Readback error from chassis management bus for fru-name fru-slot ([0xaddress, 0xoffset]
-> 0xerror-code)
Description The chassis process (chassisd) could not read back information from the Chassis
Management Bus (CMB) about the indicated component (field-replaceable unit, or FRU).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause The probable cause is hardware error.
Action Contact your technical support representative.
CHASSISD_COMMAND_ACK_ERROR
System Log Message Error occurred when fru-name fru-slot reported its online status: error-message (error
code error-code)
Description The chassis process requested that the indicated component (field-replaceable unit, or
FRU) confirm that it was online. The indicated error occurred when the FRU sent its
response. In the normal case, the chassis process performed any additional action
necessary to guarantee that the FRU came online.
Copyright © 2010, Juniper Networks, Inc.138
Junos 10.3 System Log Messages Reference