Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_COMMAND_ACK_SFM_ERROR
System Log Message function-name: SFM sfm-slot did not acknowledge FPC fpc-slot: error error-message
(code error-code)
Description The chassis process (chassisd) requires an acknowledgment from each Switching and
Forwarding Module (SFM) before it registers a Flexible PIC Controller (FPC) as online.
The acknowledgment message from the indicated SFM failed for the indicated FPC.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_CONCAT_MODE_ERROR
System Log Message Cannot set no-concatenated mode for FPC fpc-slot PIC pic-slot
Description The chassis process (chassisd) could not set channelized mode for the indicated
SONET/SDH PIC. Channelized mode is configured by including the no-concatenate
statement at the [edit chassis fpc 'slot' pic 'slot'] hierarchy level.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
CHASSISD_CONFIG_ACCESS_ERROR
System Log Message function-name: error-message
Description The chassis process (chassisd) experienced the indicated problem while attempting to
parse the configuration database.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause An internal software failure occurred.
Action Contact your technical support representative.