Facility LOG_DAEMON
CHASSISD_FCHIP_INIT_ERROR
System Log Message Fchips were not configured yet
Description The chassis process (chassisd) detected that F chips were not yet initialized.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FCHIP_LINK_ERROR
System Log Message SIBsib-slot_F0: link-type link link-id was bad
Description The chassis process (chassisd) detected an error for the indicated high-speed receiver
(HSR) or high-speed transmitter (HST) link for an F chip on the indicated Switch Interface
Board (SIB).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FCHIP_MONITOR_ERROR
System Log Message F chip module was invalid
Description The chassis process (chassisd) detected an invalid F-chip module while enabling or
disabling the monitoring of F-chip functional blocks.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FCHIP_PIO_READ_ERROR
System Log Message Fchip fchip-id: read error in function-name() for link#link-id, at address address in register
register
Description The indicated routine failed with a read error at the indicated address and register for
the indicated F chip and link.
Type Error: An error occurred
Severity error
149Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages