Description The state of the indicated component (field-replaceable unit, or FRU) changed as
indicated.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_FRU_INVALID_SLOT
System Log Message FRU fru-name is not supported in current slot
Description The chassis process (chassisd) detected that the indicated hardware component
(field-replaceable unit, or FRU) was inserted in a slot that is not valid for that component
type.
Type Error: An error occurred
Severity critical
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FRU_IO_ERROR
System Log Message function-name: fru-name operation error: reason (error-message)
Description The chassis process (chassisd) could not perform the indicated I/O operation on the
indicated component (field-replaceable unit, or FRU).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FRU_IO_OFFSET_ERROR
System Log Message function-name: fru-name operation error: reason 0xoffset (error-message)
Description The chassis process (chassisd) could not perform the indicated I/O operation at the
indicated byte offset.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.