Description The chassis process (chassisd) expects to receive notification within a timeout period
that each Flexible PIC Concentrator (FPC) has attached the PICs that it houses. It did
not receive notification from the indicated FPC.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FPC_TYPE_SIB_TYPE_ERROR
System Log Message Installed SIB type (SIB-I8-F16) does not support features required by FPC fpc-slot
Description The indicated Flexible PIC Concentrator (FPC) is Type 4, which is not supported by Switch
Interface Board (SIB) type SIB-I8-F16.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FRU_ALREADY_OFFLINE
System Log Message fru-name fru-slot already offline
Description The chassis process (chassisd) received a request to take the indicated component
(field-replaceable unit, or FRU) offline, but the FRU was already offline.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
CHASSISD_FRU_ALREADY_ONLINE
System Log Message Received request to bring fru-name fru-slot online; it was already online
Description The chassis process (chassisd) received a request to bring the indicated component
(field-replaceable unit, or FRU) online, but the FRU was already online.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
CHASSISD_FRU_EVENT
System Log Message function-name: state fru-name fru-slot