Facility LOG_DAEMON
Cause The probable cause is hardware error.
Action Contact your technical support representative.
CHASSISD_GBUS_READBACK_ERROR
System Log Message Readback error from GBUS for fru-name fru-slot ([0xgbus-address, 0xgbus-registers] ->
0xreturn-value)
Description There was an error when the chassis process (chassisd) tried to read back information
from the GBUS on the indicated component (field-replaceable unit, or FRU).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause The probable cause is hardware error.
Action Contact your technical support representative.
CHASSISD_GBUS_RESET_EVENT
System Log Message fru-name#fru-slot - command
Description The chassis process (chassisd) reset the GBUS for the indicated component
(field-replaceable unit, or FRU). This is a normal part of startup.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
CHASSISD_GBUS_SANITY_ERROR
System Log Message function-name: fru-name fru-slot -- management bus failed sanity test
Description The chassis process (chassisd) checks its management GBUS with a set of test operations
when it is started. The tests failed.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_GENERIC_ERROR
System Log Message function-name: error-message